Last updated: 5 Jan 2023 | 678 Views |
◎ Models Installed: AF Series - Submersible Sewage / Wastewater Pumps
IC Series - Submersible Dewatering Pumps
◎ Description:
Taiwan has many natural harbors. These busy harbors are crowded that the ships must be inspected at a separate repair dock for annual checkups. The repair dock is built with pits to compensate vessels with unique designs. These pits require submersible pumps to extract the seawater. 9 HCP PUMP is installed in the pits: 6 AF Series Submersible Sewage Pumps, 2 30HP 150(200)AFE422, 4 15HP 100(150)AFE411, and 3 5HP IC Series IC-45B. At 5m head, the 150(200)AFE422 can pump 6.8m3/min, the 100(150)AFE411 can pump 4m3/min, and the IC-45B, pump 1m3/min at 13m head. The pumps help the dock staff to inspect and repair the ships speedily and safely.